DR-60W series Din-rail powerupply
Features:
· universal ACinputrange
· Small volume,low weight,high efficientency
· Praesidia: ambitus brevis/per onus/per voltage
· refrigerationem libero aere convection
·instrui potest onDINrail:TS-35/7.5or TS-35/15
· DUXERIT indicator pro potentia on
·100% plenum onus uri-in test
·2 Years warranty
Model | DR-60-5 | DR-60-12 | DR-60-24 | |
output " | DC voltage | 5V | 12V | 24V |
tolerantia intentione | ±2% | ±1% | ±1% | |
Ratum current | 6.5A | 4.5A | 2.5A | |
Current range | 0~6.5A | 0~3.5A | 0~2.5A | |
Rated potestas | 32.5W | 54W | 60W | |
Ripple & noise | 100mvp-p | 100mvp-p | 150mvp-p | |
DCvoltage ADJ.range | -9%~+10% | ±10% | ±10% | |
input | Voltage range | 90~ 264VAC,127~373VDC | ||
frequentia | 47~63HZ | |||
AC current | 1.2A/110VAC,0.65A/220VAC | |||
efficientiam | 76% | 82% | 84% | |
Incurrere current | Initium frigidum currentis 25A/115VAC,50A/230VAC | |||
Lacus current | < 1mA/240VAC | |||
praesidium | Per onus | Rated output power105% ~ CL% satus super onus praesidium | ||
genus praesidio: singultus modus-auto-recuperatio post culpam conditione remotum est | ||||
in voltage | 6.8~8.2V | 15.6~17.8V | 30.6~33.2V | |
praesidium type: abscissus output voltage, diode Fibulae | ||||
environment | Opus temp, humiditas | -20℃~+60℃,20%~90%RH | ||
Repono temp, humiditas | -40℃~+85℃,10%~95%RH non-condensing | |||
sustinere vibrationis | X ~ 500HZ 2G10min / 1cycle,tempus LX minuta (per axes) | |||
salus | sustinere voltage | I/PO/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | ||
Repugnantia solitudo | I/PO/P,I/P-FG,O/P-FG:100Mohms/500VDC | |||
Fit vexillum | vexillum salus | Obsequens UL1012 | ||
EMC vexillum | Obsequens EN55022,CLASSA | |||
alii | Dimension | 78*93*56mm(L*W*H) | ||
Pondus / sarcina | 0.3kg/48pcs/15.4kg/0.03m³/1.07CUFT | |||
nota | 1. Omnes parametri NON nominatim metiuntur 230VAC initus, aestimatio oneris ac 25℃ ambientis temperatus. 2. Ripple & sonitus mensurae sunt ad 20MHz latitudo, utendo 12″ filo gemino contorto terminato 0.1uf & 47uf capacitatis parallelae. 3. Tolerantia : includuntur erecta tolerantia, recta ordinatio et oneris expers. |