Adjustable iPad Stand, Tablet Stand Holders.
LRS-200Wseries Ultra tenues unius commutatione potentiae copia
Features:
·AC input range selectus per switch (115/230)
· Withstand300VAC impetus initus est pro 5 secundo
· Minaturesize et 1U humilis profile, humilis pondus
· Praesidia: Shortcircuit / ONERO/Per intentione/Per caliditas
· Coolingby liberum caeli convection
·Noload potentia consummatio<0.75W
· Operatingaltitude usque ad (V) metris(Note6)
· LEDindicator pro potentia on
·100% plenum onus incendat in test
·Highfficiency, long life and high reliability
· 3years warranty
Model | LRS-200-5 | LRS-200-12 | LRS-200-15 | LRS-200-24 | LRS-200-36 | LRS-200-48 | |
output " | DC voltage | 5V | 12V | 15V | 24V | 36V | 48V |
Ratum current | 40A | 17A | 14A | 8.8A | 5.9A | 4.4A | |
Current range | 0~40A | 0~17A | 0~14A | 0~8.8A | 0~5.9A | 0~4.4A | |
Rated potestas | 200W | 204W | 210W | 211.2W | 212.4W | 211.2W | |
Ripple & noise | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | |
DC intentione ADJ.range | ±10% | ±10% | ±10% | ±10% | ±10% | ±10% | |
intentione toleranceNote.3 | ±3% | ±2% | ±1% | ±1% | ±1% | ±1% | |
Line regulationNote.4 | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Load regulationNote.5 | ±2% | ±1% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Setup, surgere, tenere in tempore | 800ms, 50ms, 16ms/230VAC (plenum onus) | ||||||
input | Voltage range | 90~ 132VAC/180~ 264VAC(selectus per transitum) ,240~373VDC | |||||
Frequency range | 47~63HZ | ||||||
AC current | 4.0A/115VAC 2.2A/230VAC | ||||||
Incurrere current | Committitur frigus 50A/230VAC | ||||||
Efficientia | 85% | 87% | 88% | 89% | 89% | 90% | |
Lacus current | <2mA/240VAC | ||||||
praesidium | cultro | Rated output power110% ~ CXL% satus super onus praesidium | |||||
genus praesidio: singultus modus-auto-recuperatio post culpam conditione remotum est | |||||||
Per voltage | Rated output voltage CXV% ~ CXXXV% Satus super voltage praesidium | ||||||
Tutela type singultus modus auto- recuperatio post culpam conditio tollitur | |||||||
Plus temperatus | 100℃±10℃(RTH3 deprehendere iuxta nucleum magneticum | ||||||
Tutela type: abscinde output, auto-recuperatio post temperatus facti normales | |||||||
environment | Opus temp, humiditas | -25℃~+70℃ (Quaeso ad "curvam")20%~90% RH Non-condensing | |||||
Repono temp, humiditas | -40℃~+85℃,10%~95%RH non-condensing | ||||||
sustinere vibrationis | X ~ 500HZ 2G10min / 1cycle,tempus LX minuta (per axes) | ||||||
salus | sustinere voltage | I/PO/P:3KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC | |||||
Repugnantia solitudo | I/PO/P,I/P-FG,O/P-FG:100Mohms/500VDC | ||||||
Fit vexillum | salus signa | Obsequium ad UL60950-1, TUV EN60950-1, GB4943 | |||||
EMC emissio | Obsequens EN55032(CISPR22)Class A,GB9254 Class B, EN55014, EN61000-3-2,3 | ||||||
immunitas EMC | Obsequens EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-1 | ||||||
alii | Dimension | 215*115*30mm(L*W*H) | |||||
Pondus / sarcina | 0.66kg/20pcs/14.2kg/0.024m³/0.85CUFT | ||||||
MTBF | ≥320K hrs min.MIL-HDBK-217F(25℃) | ||||||
nota | 1. Omnes parametri NON nominatim metiuntur 230VAC initus, onus aestimatus et 25℃ temperatus ambientis. 2. Ripple & sonitus mensurae sunt ad 20MHz latitudo, utendo 12″ filo gemino contorto terminato 0.1uf & 47uf capacitore parallelo. 3. Tolerantia : includuntur erecta tolerantia, recta ordinatio et oneris expers. 4.Line moderatio mensuratur ab low linea ad altam lineam at aestimavit onere. 5.Load ordinatio mensuratur ab 0% ad C% onus rated 6. Temperatura ambientium 5℃/1000 m cessionis opus est ad altitudinem operandam maiorem quam 2000m(6500ft) 7. Potestas copia pro compositione consideratur quae in finale equipmentum instituetur. Supremum instrumentum iterum confirmandum est quod adhuc occurrit EMC normae. Ductio enim quomodo haec EMC probationes perficiendi. |