SC-60W series UPS tergum potentia copia
Features:
Universale AC inputrange
· Small volume,low weight,high efficientency
· Praesidia: brevis circuitus/per onus
· Testimonium pro potentia in / crimen / electrica copia (DUXERIT)
·100% plenum onus uri-in test
· Pugna ad praesidium humilis voltage
·2 Years warranty
Model | SC-35-12 | SC-35-24 | |||
output " | DC voltage | CH1:13.8V | CH2:13.4V | CH1:27.6V | CH2:26.5V |
tolerantia intentione | ±2% | -- | ±1% | -- | |
Ratum current | 2.0A | 0.5A | 1.0A | 0.3A | |
Current range | 0~2.0A | -- | 0~1.0A | -- | |
Rated potestas | 34.3W | 35.6W | |||
Ripple & noise | 120mvp-p | -- | 120mvp-p | -- | |
DCvoltage ADJ.range | CH1:11.3~14.9V | CH1:21.3~29.8V | |||
Setup, oriri, tenere tempus | 800ms, 50ms, 80ms/230VAC, 1600ms, 50ms, 16ms/115VAC | ||||
input | Voltage range | 90~ 264VAC,127~ 370VDC | |||
frequentia | 47~63HZ | ||||
AC current | 0.9A/115VAC,0.45A/230VAC | ||||
efficientiam | 81% | 83% | |||
Incurrere current | Initium frigidum currentis 25A/115VAC,45A/230VAC | ||||
Lacus current | < 1mA/240VAC | ||||
praesidium | Per onus | Rated output power110% ~ CL% satus super onus praesidium | |||
praesidium modus: AC præcipiens modus: singultus modus auto- recuperatio post culpam conditione removetur | |||||
Pugnaprotection At humilis voltage | 9.5~11V | 20~22V | |||
tutela modus: intervalli output | |||||
Officium | UPS introductio | longum tempus online fluitans crimen ad pugnas, efficientiam altam increpans, altilium potest saturare plus quam 90% , cauto-stare, cum plenum est, praeveniendo praecipiens.Efficaciter extendunt altilium vita, AC/altilium autocinetum, nulla commutatio temporis, nulla custodia humana; frigus-satus, cum nulla AC initus est, uti potest altilium satus UPS, occurrit usoris necessitates subitis | |||
environment | Opus temp, humiditas | -10℃~+60℃,20%~90%RH | |||
Storagetemp, humiditas | -20℃~+85℃,10%~95%RH non-condensing | ||||
sustinere vibrationis | X ~ 500HZ 2G10min / 1cycle,tempus LX minuta (per axes) | ||||
salus | sustinere voltage | I/PO/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||
Repugnantia separatim | I/PO/P,I/P-FG,O/P-FG:100Mohms/500VDC | ||||
Fitstandard | vexillum salus | Obsequium ad UL60950-1 | |||
EMC vexillum | Obsequens EN55022,CLASSB | ||||
alii | Dimension | 111*78*36mm (L*W*H) | |||
Pondus / sarcina | 0.3kg/50pcs/16kg/0.027m³/0.96CUFT | ||||
nota | 1. Omnes parametri NON nominatim metiuntur 230VAC initus, aestimatio oneris ac 25℃ ambientis temperatus. 2. Ripple & sonitus mensurae sunt ad 20MHz latitudo, utendo 12″ filo gemino contorto terminato 0.1uf & 47uf capacitore parallelo. 3. Tolerantia : includuntur erecta tolerantia, recta ordinatio et oneris expers. |